Check the text detector against HaN-Seg#

Under the Clean Pixel Data Option, the de-identification engine gives each frame of the pixel data to a text detector, blacks out every region that it finds, and holds the instance for review (D-037 in the de-identification design). The Text Detector Check workflow gives the same detector the slices of the HaN-Seg data set’s 42 head and neck planning CTs and 42 T1-weighted MRs, and publishes only counts of the slices and regions that it finds.

HaN-Seg’s images hold no burned-in text, as far as the project knows, so each region counted is one that a run would black out in error, over anatomy unless the region is all air, and that a reviewer would have to clear. That is an inference, not something the check measures; the counts are the option’s only evidence on real images of the anatomy in scope.

The check counts false positives alone, on two IODs of one body site. Measuring missed text and false positives together, on images with and without burned-in text across the IODs in scope, and tuning the detector against criteria set beforehand, is designed in D-056; its library is described under Measuring missed text as well, and its tuning runs and the adoption of a tuned detector are not yet made, so this check’s counts remain the detector’s evidence on these images until then.

The data set#

The check uses HaN-Seg version 1.0, as the face block check does, under the same rules (D-054): only the workflow’s runner downloads it, from Zenodo, and checks it against the size and MD5 that the record gives; the runner reads it from its ZIP file without extracting it; and only counts, codes, digests, versions, and the detector’s method leave the runner. Its images are of real patients, so the project treats them as real patient data: never commit, cache, or attach any part of the data set, or a value read from it. See Check the face block against HaN-Seg for the record, its licence, and its citation.

Run the check#

  1. In the repository’s Actions tab, choose Text Detector Check, then Run workflow, and pick the branch whose detector to check.

  2. Two jobs run side by side, one for the CTs (CT) and one for the MRs (MR_T1). Each downloads HaN-Seg.zip from Zenodo, checks its size and MD5 against the record’s, and runs the check with a process for each of the runner’s CPUs.

  3. Each job’s summary shows its results, and its artefact pixel-text-validation-results-CT or pixel-text-validation-results-MR_T1, kept for 90 days, holds pixel-text-validation.json, pixel-text-validation.md, and commit.txt, the commit checked.

Each job runs python -m pymedphys._dicom.deidentify.pixel_text_validation_command hanseg <HaN-Seg.zip> --image <CT or MR_T1> --workers <CPUs> --out <directory> through .github/scripts/run_redacted.py, which reports a crash by its type and code locations alone, and keeps the command’s standard output and standard error, where libraries log, in files on the runner. The command makes the detector as a run under the option makes it, with the pinned model, which it downloads from PyPI on first use, and its default parameters. Each worker process has its own detector of one thread, so the regions do not depend on how many workers run. The detector takes seconds a slice, so a job takes hours; each has almost the six hours that a hosted runner allows.

What the counts show#

Each volume is given to the detector as a run gives it a series of its slices: one frame for each slice along the volume’s third axis, its values, rounded where they are not integers, as stored values. The detector’s renderings depend only on the stored values’ minimum, maximum, and differences, so HaN-Seg’s CTs, stored in Hounsfield units, give the regions that the same CTs would with a rescale intercept.

Section

What it counts

Volumes

The volumes of the image in the ZIP file, those measured, those not measured by why, such as not-read/data-length, and crashes by the exception’s type and place in the code; how each was stored; the plane of its slices, named by the patient’s axis within 10 degrees of their normal, or oblique; the larger side of a slice, in pixels; and the larger spacing within a slice.

Slices

The slices searched, those with a region, the regions, and the slices by how many regions each gives.

Volumes by their regions

The volumes with a region, the volumes by how many regions each gives, and by the share of their slices with a region.

Regions

Each region’s area as a share of its slice’s, its shorter side in pixels, its longer side over its shorter, and, for CT, the share of its pixels above -900 HU, where the region would black out more than air; then each region’s score margin and the renderings that gave it.

By the larger side of a slice

For each bin of the larger side of a slice, in pixels: the volumes, the slices searched, the slices with a region, and the regions; and, for the bins that hold a volume, the regions by score margin and by the renderings that gave them.

By the larger spacing within a slice

The same, for each bin of the larger spacing within a slice, in millimetres.

A region’s score margin is the highest mean probability that any of the detector’s three renderings (its full range and its white and black top-hats) gave the region’s box, less the detector’s box threshold, 0.5 by default. A box is kept while any rendering gives it, so the regions with a margin of at least some amount are those that the same detector would keep with its box threshold raised by that amount, every other parameter unchanged. Raising the box threshold could also lose text that the detector now finds, which this check cannot show, since HaN-Seg holds none.

The summary is labelled pymedphys-deid-pixel-text-validation/2. It also gives the detector’s method as the method digest of a run takes it: the finder’s class, the model’s SHA-256, the ONNX Runtime version and distributions, the NumPy and SciPy versions, the detection parameters, and the renderings. Each measure is counted in fixed bins, and no case is named, so the summary gives no value of any case.

Results on main#

The check ran on main at commit d3c67ee1e56e9d161a131061484f7ceec364cf26 on 26 October 2026, in run 40286977414, whose two jobs both succeeded. Their artefacts expire on 24 January 2027, so their counts are recorded here, as the job summaries give them. The run predates the /2 summary: its summaries are labelled /1, and have no score margins, no renderings, and no counts by the larger side of a slice or the larger spacing within one.

About

Summary

pymedphys-deid-pixel-text-validation/1

Data set

HaN-Seg 1.0, doi:10.5281/zenodo.7442914

File

4938848306 bytes, MD5 c3d3070de3034933a63031b73b9cf0fc, SHA-256 20226dd717f334dc1b1afe961b3375f946fa56b64a80bf5349128f90c0bbfa5f

Software

Python 3.14.8, pymedphys 0.42.0.dev1, NumPy 2.5.4, SciPy 1.18.1, ONNX Runtime 1.31.0

Finder

pymedphys._dicom.deidentify.text_detection.TextDetector, with its default parameters

Model SHA-256

090f04abcd9d9a7498bc4ebf677e4cb9bdce1fe4197ddb7e529f1ef44e1ff94f

Artefact pixel-text-validation-results-CT

3737 bytes as uploaded, SHA-256 09f316a2e66307ca3a0169d73afa7663c156f4534094ebcc0f573df77feac2e9

Artefact pixel-text-validation-results-MR_T1

3466 bytes as uploaded, SHA-256 687fb9165b5167ad9487ef2ef8fd46977af0c371dbbe0241e406f3f7d777a0cb

Volumes#

Volumes

CT

MR_T1

In the data set

42

42

Measured

42

42

Stored as int16 gzip left-posterior-superior

31

36

Stored as int32 gzip left-posterior-superior

11

0

Stored as uint16 gzip left-posterior-superior

0

6

With axial slices

42

42

Larger side of a slice (pixels)

CT volumes

MR_T1 volumes

0 to under 256

0

0

256 to under 384

0

0

384 to under 512

0

0

512 to under 640

7

42

640 to under 768

0

0

768 to under 1024

0

0

1024 or more

35

0

Larger spacing within a slice (mm)

CT volumes

MR_T1 volumes

0 to under 0.5

0

27

0.5 to under 0.75

35

14

0.75 to under 1

5

1

1 to under 1.25

1

0

1.25 to under 1.5

0

0

1.5 to under 2

1

0

2 or more

0

0

Slices#

Slices

CT

MR_T1

Searched

7581

3613

With a region

7162

719

Regions

33183

953

Regions in a slice (regions)

CT slices

MR_T1 slices

0 to under 1

419

2894

1 to under 2

993

540

2 to under 3

1133

134

3 to under 4

1066

36

4 to under 5

968

8

5 to under 10

2388

1

10 to under 20

611

0

20 or more

3

0

Volumes by their regions#

Every volume of each image gave at least one region: 42 CTs and 42 MRs.

Regions in a volume (regions)

CT volumes

MR_T1 volumes

0 to under 1

0

0

1 to under 2

0

0

2 to under 5

0

1

5 to under 10

0

3

10 to under 20

0

14

20 to under 50

0

24

50 to under 100

0

0

100 to under 200

2

0

200 to under 500

6

0

500 to under 1000

25

0

1000 or more

9

0

Share of a volume’s slices with a region (share)

CT volumes

MR_T1 volumes

0 to under 0.1

0

2

0.1 to under 0.2

0

19

0.2 to under 0.3

0

17

0.3 to under 0.4

0

4

0.4 to under 0.5

0

0

0.5 to under 0.6

1

0

0.6 to under 0.7

2

0

0.7 to under 0.8

1

0

0.8 to under 0.9

2

0

0.9 to under 1

21

0

1 or more

15

0

Regions#

Area (share of the slice)

CT regions

MR_T1 regions

0 to under 0.0005

1615

0

0.0005 to under 0.001

4410

0

0.001 to under 0.002

8910

25

0.002 to under 0.005

10227

167

0.005 to under 0.01

3942

203

0.01 to under 0.02

2126

228

0.02 to under 0.05

1886

287

0.05 to under 0.1

65

40

0.1 or more

2

3

Shorter side (pixels)

CT regions

MR_T1 regions

0 to under 8

0

0

8 to under 12

0

0

12 to under 16

91

1

16 to under 24

3635

50

24 to under 32

5388

140

32 to under 48

9465

277

48 to under 64

5217

195

64 to under 96

6139

250

96 or more

3248

40

Longer side over shorter (ratio)

CT regions

MR_T1 regions

1 to under 1.5

27571

637

1.5 to under 2

3592

202

2 to under 3

1498

104

3 to under 5

485

10

5 to under 10

37

0

10 or more

0

0

Share of the region’s pixels above -900 HU (share)

CT regions

0 to under 0.1

36

0.1 to under 0.2

261

0.2 to under 0.3

1798

0.3 to under 0.4

4516

0.4 to under 0.5

3913

0.5 to under 0.6

3446

0.6 to under 0.7

2783

0.7 to under 0.8

1779

0.8 to under 0.9

1431

0.9 to under 1

3142

1 or more

10078

Reading these counts#

  • On CT, the detector found a region in 94.5% of the slices searched and in every volume, 4.38 regions for each slice searched. Of its 33,183 regions, 22,659 (68%) have half or more of their pixels above -900 HU, and 10,078 (30%) have all of them, so most would black out tissue rather than air.

  • On MR, it found a region in 19.9% of the slices and in every volume, 0.26 regions for each slice searched.

  • If, as above, HaN-Seg’s images hold no burned-in text, every one of these regions is a false positive. A reviewer can add a region to a cleaned instance but cannot remove one that the finder found (D-048), so a cleaned slice like these is released with every region blacked out, or rejected.

  • 35 of the 42 CTs have slices of 1024 pixels or more on their larger side, and every MR has slices of 512 to under 640. These /1 summaries do not count regions by slice size, so they do not show whether size explains the difference between CT and MR; the /2 summary counts them so, and its rerun is recorded below.

  • The counts are evidence, not a verdict: whether the detector’s false positives on CT and MR are acceptable is decided by the evaluation that D-056 designs, which measures them with missed text on the same images against acceptance criteria set before tuning, and the validation table of the design doc waits on its held-out confirmation.

Results by slice size and score margin#

The check ran again at commit 904b15d6fcec766a73f0d7532aee94d54873c3b0, the change that added the /2 summary, now on main, in run 41145832882 on 31 October 2026, whose two jobs both succeeded. An earlier run at the same commit, 41145744256, gave the same summaries, value for value. Their artefacts expire on 28 January 2027, so their counts are recorded here, as the summaries give them. Every count that the /1 summary also gives is the same as in the run on main above, so only the counts that /2 adds are shown.

About

Summary

pymedphys-deid-pixel-text-validation/2

Data set

HaN-Seg 1.0, doi:10.5281/zenodo.7442914, the same file as above

Software

Python 3.14.9, pymedphys 0.42.0.dev1, NumPy 2.5.4, SciPy 1.18.1, ONNX Runtime 1.31.0

Finder

pymedphys._dicom.deidentify.text_detection.TextDetector, with its default parameters, box threshold 0.5

Model SHA-256

090f04abcd9d9a7498bc4ebf677e4cb9bdce1fe4197ddb7e529f1ef44e1ff94f

Artefact pixel-text-validation-results-CT

5564 bytes as uploaded, SHA-256 e5b39d9b7489b944e1b63eb5b291b7db817b5966d06ca3a4c598f24d97dc977c

Artefact pixel-text-validation-results-MR_T1

4911 bytes as uploaded, SHA-256 04bd1ce00bd56037d7f184690efb76b794330aaf869c6fbafe3e372774e8f204

Regions by score margin and rendering#

Score margin (mean probability above the box threshold)

CT regions

MR_T1 regions

0 to under 0.025

1822

106

0.025 to under 0.05

1862

73

0.05 to under 0.1

3906

210

0.1 to under 0.15

4482

132

0.15 to under 0.2

5155

128

0.2 to under 0.25

5932

152

0.25 to under 0.3

4996

98

0.3 to under 0.35

3932

41

0.35 to under 0.4

962

13

0.4 to under 0.45

134

0

0.45 or more

0

0

Renderings that gave the region

CT regions

MR_T1 regions

black-top-hat

18516

401

full-range

4715

29

full-range+white-top-hat

114

0

white-top-hat

9838

523

By the larger side of a slice#

Every other bin of the larger side of a slice holds no volume of either image.

Image and larger side of a slice (pixels)

Volumes

Slices searched

Slices with a region

Regions

CT, 512 to under 640

7

1132

841

1646

CT, 1024 or more

35

6449

6321

31537

MR_T1, 512 to under 640

42

3613

719

953

Score margin

CT, 512 to under 640 pixels

CT, 1024 or more pixels

MR_T1, 512 to under 640 pixels

0 to under 0.025

101

1721

106

0.025 to under 0.05

117

1745

73

0.05 to under 0.1

188

3718

210

0.1 to under 0.15

220

4262

132

0.15 to under 0.2

237

4918

128

0.2 to under 0.25

382

5550

152

0.25 to under 0.3

253

4743

98

0.3 to under 0.35

104

3828

41

0.35 to under 0.4

43

919

13

0.4 to under 0.45

1

133

0

0.45 or more

0

0

0

Renderings

CT, 512 to under 640 pixels

CT, 1024 or more pixels

MR_T1, 512 to under 640 pixels

black-top-hat

678

17838

401

full-range

497

4218

29

full-range+white-top-hat

6

108

0

white-top-hat

465

9373

523

By the larger spacing within a slice#

Every other bin of the larger spacing within a slice holds no volume of either image.

Image and larger spacing within a slice (mm)

Volumes

Slices searched

Slices with a region

Regions

CT, 0.5 to under 0.75

35

6449

6321

31537

CT, 0.75 to under 1

5

869

650

1274

CT, 1 to under 1.25

1

122

107

211

CT, 1.5 to under 2

1

141

84

161

MR_T1, 0 to under 0.5

27

1866

388

503

MR_T1, 0.5 to under 0.75

14

1707

323

441

MR_T1, 0.75 to under 1

1

40

8

9

Score margin

CT, 0.5 to under 0.75 mm

CT, 0.75 to under 1 mm

CT, 1 to under 1.25 mm

CT, 1.5 to under 2 mm

MR_T1, 0 to under 0.5 mm

MR_T1, 0.5 to under 0.75 mm

MR_T1, 0.75 to under 1 mm

0 to under 0.025

1721

70

16

15

54

50

2

0.025 to under 0.05

1745

82

12

23

38

35

0

0.05 to under 0.1

3718

139

29

20

110

98

2

0.1 to under 0.15

4262

150

43

27

78

54

0

0.15 to under 0.2

4918

156

50

31

64

64

0

0.2 to under 0.25

5550

328

35

19

85

65

2

0.25 to under 0.3

4743

222

13

18

52

45

1

0.3 to under 0.35

3828

88

9

7

15

25

1

0.35 to under 0.4

919

39

3

1

7

5

1

0.4 to under 0.45

133

0

1

0

0

0

0

0.45 or more

0

0

0

0

0

0

0

Renderings

CT, 0.5 to under 0.75 mm

CT, 0.75 to under 1 mm

CT, 1 to under 1.25 mm

CT, 1.5 to under 2 mm

MR_T1, 0 to under 0.5 mm

MR_T1, 0.5 to under 0.75 mm

MR_T1, 0.75 to under 1 mm

black-top-hat

17838

544

70

64

230

163

8

full-range

4218

353

79

65

10

19

0

full-range+white-top-hat

108

3

2

1

0

0

0

white-top-hat

9373

374

60

31

263

259

1

What the new counts show#

  • The 35 CTs whose slices are 1024 pixels or more on their larger side gave 31,537 of the 33,183 CT regions (95.0%): a region in 98.0% of their 6,449 slices, and 4.89 regions for each slice searched. The other 7 CTs, of 512 to under 640 pixels, gave a region in 74.3% of their 1,132 slices, 1.45 regions for each, and the MRs, all of 512 to under 640 pixels, gave a region in 19.9% of theirs, 0.26 for each.

  • Inference, not measured: at the same slice size, CT still gives a region in far more slices than MR, so slice size alone does not explain the difference between them, though among the CTs the larger slices give 3.4 times as many regions for each slice. The smaller bin holds only 7 CTs, so that comparison rests on few patients.

  • On CT, the bin of 1024 pixels or more and the bin of 0.5 to under 0.75 mm give the same counts in every column, so as far as the counts show they hold the same 35 volumes, and these data cannot separate slice size from spacing. On MR, slices under 0.5 mm and of 0.5 to under 0.75 mm gave a region at nearly the same rate, 20.8% and 18.9%.

  • A box threshold raised from 0.5 to 0.6, 0.7, 0.8, or 0.9, every other parameter unchanged, would keep 77.1%, 48.1%, 15.2%, or 0.4% of the CT regions, and 59.2%, 31.9%, 5.7%, or none of the MR regions. On CT the share kept at 0.7 is nearly the same for both slice sizes, 47.6% and 48.1%. These counts give the regions kept only at the edges of the bins, and cannot show what text a raised threshold would miss, since HaN-Seg holds none.

  • Almost every region was given by one rendering alone. On CT, the black top-hat gave 55.8% of the regions, the white top-hat 29.6%, the full range 14.2%, and the full range and white top-hat together 0.3%; on MR, the white top-hat gave 54.9%, the black top-hat 42.1%, and the full range 3.0%. For each slice searched, the CTs of 1024 pixels or more gave 4.6 times as many black top-hat regions as the CTs of 512 to under 640, 3.5 times as many white top-hat regions, and 1.5 times as many full-range regions, so most of the increase with slice size is in the top-hat renderings.

  • These counts show where the false positives arise, not how to remove them: whether a change to the renderings or to the box threshold would remove them without losing text needs images with known text, which HaN-Seg lacks.

Measuring missed text as well#

This check counts only regions on images without text. The text detector’s evaluation library (D-056), in the modules pymedphys._dicom.deidentify.text_evaluation and text_evaluation_*, measures both sides of the trade-off on the same images: it burns synthetic text of known ink, in fonts, heights, contrasts, styles, orientations, and positions that a plan lists, into synthetic phantoms and, on a runner, into real images without text, and counts the text fully covered beside the regions on frames without text and away from the text. A text is fully covered when the boxes cover every pixel of its core ink, the pixels more than half ink (or all its ink, where no pixel is), and missed when they cover none of that core; whether every pixel with any ink is covered is counted beside, since a covered core does not prove that the fringe left over cannot be read. Its text is drawn in bitmap fonts, its own and Pillow’s, and in fonts under the SIL Open Font License, version 1.1 (Source Sans Pro, Source Serif Pro, Lato, Noto Sans, FiraGO, Fira Mono, and Space Mono), which PyMedPhys does not ship: each is fetched from a wheel on the Python Package Index when first drawn, and used only if the wheel and the font have the SHA-256 digests pinned in text_evaluation_font_files, which also records each font’s copyright and licence. It evaluates a grid of post-processing settings from one pass of the network, and detector variants that only a check can select, never a run. Cases are split by a fixed rule into a tuning part and a held-out part, by the patient where a source knows one, so that one patient’s series all fall in the same part, and the bootstrap resamples patients, not cases, so that a patient’s series are not treated as independent. Every point of the grid is counted in every stratum, so the criteria can compare each with today’s settings, and its summary, labelled pymedphys-deid-text-detector-evaluation/1, gives only counts, shares, and their intervals, never a value or a case.

The acceptance criteria, chosen before any tuning run and held in text_evaluation_criteria, require, for texts at least 7 frame pixels high, whether drawn in pixels or in millimetres, at least 99% fully covered in every cell of IOD, contrast, and height where the text stands 16 or more times the noise above its background, and at least 95% from 4 to under 16 times; on frames without text, a region on at most 2% of CT, MR, and PET frames, Legacy Converted Enhanced ones included, and 5% of RT Image, CR, DX, and XA frames, in each IOD and in each bin of slice size, with every other image IOD held to the stricter 2% until it is given a group, and at most 0.01% of tissue blacked out in any; an IOD without 300 frames known to be free of text fails; no text of MIDI-B’s answer key missed entirely, read from the frames of its tier of the corpus, which each case names; and no single stratum more than 2 percentage points worse than today’s settings. Each limit must hold at the unfavourable end of both the Wilson interval and the bootstrap interval over subjects (patients where known, cases otherwise), and a cell of fewer than 400 texts or 300 frames fails, as does a cell of contrast and height that the criteria judge but in which an IOD has no text at all, so that an IOD is never passed on the cells it happens to have, such as one whose colour frames took no injected text. Cells below those contrasts and heights are reported, not judged. A stratum counted at one point and not at today’s settings fails the loss rule, rather than being left out of it. The assessment also gives, for each IOD measured, the review that its frames need: only the frames that the detector flags, where the detector is adoptable and no criterion fails for the IOD’s own cells, and every frame otherwise. A failure that no single IOD’s cells hold, such as a missed answer-key text or a loss in a collection’s or modality’s stratum, counts against every IOD, and an IOD that the evaluation did not measure needs every frame reviewed. Failing the criteria does not bar the Clean Pixel Data Option from an IOD; it only takes away flagged-only review, as the maintainer decided on 1 November 2026.

It also reads a folder of DICOM files on the machine of someone allowed to use them, such as a department’s own RT Images, grouped into cases by patient and named only by a digest, which also serves as the patient for the split and the bootstrap. Their text as read is unknown, unless someone drew boxes around it in a CSV file of annotations, so regions on them are counted apart from false positives, as regions where text is unknown, and text injected into them is counted as on any other image: each injected text is fully covered, partly covered, or missed, with none of its core ink covered, and counted in fixed bins of the share of its core ink covered. The text is drawn into copies of the images held in memory, so nothing is written to that machine’s disk. Only the summary leaves that machine, and only if its owner chooses.

Real patients’ scans in openly licensed collections of NCI’s Imaging Data Commons are read on CI’s runners alone, through the module text_evaluation_idc. It takes a series from IDC’s index only where its collection is one of those vetted, by IDC’s collection_id, IDC gives it the same licence as was vetted (CC BY 3.0 or 4.0, CC BY-NC 3.0 or 4.0, CC0, or PDDL), it carries a DOI, its modality is one of an image that may hold burned-in text, and, in the fourteen collections taken only for their screen captures, Nuclear Medicine, and ultrasound images, its SOP Class is one of those; where IDC’s licence and the vetted one differ, the series is refused, and every refusal is counted by its reason. MIDI-B’s source collection is taken only less the series that MIDI-B’s answer key marks. Each collection’s series are taken in an order fixed by a digest, up to a number and a size, and written as an s5cmd manifest; each downloaded series is read as one case, of tier T3, whose patient, for the split and the bootstrap, is a salted digest of its collection and IDC’s PatientID, which stays on the runner and is never written to a summary or report, whose frames are taken to hold no text, as these collections were curated for public release: a region on one of them counts as a false positive, so the criteria’s limits on regions in frames without text apply to them, and the zones of the summary show where curation may have left text. The frames of those fourteen collections, whose screen captures and ultrasound commonly carry text, are the exception: their text is taken as unknown, so a region found on one as received is counted apart from the false positives, and the text burned into them measures missed text. Beside them, the same workflow reads folders of openly licensed archives, through the module text_evaluation_archives: five Zenodo records, of head CT angiography, bone scintigraphy with multi-frame Nuclear Medicine, dental cone-beam CT, and volunteers’ Enhanced MR, and the RT Images of the BRAVEHeart breast radiotherapy trial, from the University of Sydney’s research data store, whose text is taken as unknown. Each archive is pinned by its size, the SHA-256 of its central directory, and either the MD5 that its Zenodo record gives it or its path in the Sydney store, and read in place over HTTP ranges; whole leaf folders are taken in an order fixed by a digest, up to a number and a size, and, in BRAVEHeart’s archives, only the folders that held RT Images when they were pinned; each member is written under a digest of its name, and, from BRAVEHeart, only RT Images are written. These are counted only: the per-case report withholds them. For these series alone, the module text_evaluation_cases gives a per-case report beside the counts-only summary, which it leaves as it is: each series by its collection_id and Series Instance UID, with its licence and DOI, and for each setting its counts of texts fully covered, partly covered, and missed, and of frames with a region, never a pixel value or a crop. The seven collections taken from The Cancer Imaging Archive under CC BY or CC BY-NC are read from the Imaging Data Commons’ copy of them, which held the same image series as TCIA’s public listing under the same licences when it was checked on 7 November 2026, and are reported in the same way, by TCIA collection name and Series Instance UID, as the maintainer confirmed on 1 November 2026, and only under one of those licences; so Pediatric-CT-SEG, which the split holds out whole, is held out by that name. Every other case is counted as withheld.

The Text Detector Evaluation workflow (.github/workflows/text-detector-evaluation.yml), started by hand with the model, its settings, the part of the split, and the budgets as inputs, runs these in one job and, in a second job on a runner of its own, the phantoms: it selects series of IDC’s three allow-listed phantom collections alone (idc-select --phantoms), CC-Radiomics-Phantom-3, RIDER PHANTOM PET-CT, and VICTRE, whose files carry TCIA’s project block naming them, and reports them and the synthetic phantoms in full (phantom-report), with the counts-only summary, each case’s report, PNG crops of its regions and of the texts not fully covered, and the collections’ attribution. The command refuses a selection that holds any other collection, and, unless the whole corpus is evaluated, reports only the cases in the part of the split evaluated, so that no case held out is previewed while the detector is tuned.

To measure Legacy Converted Enhanced CT, MR, and PET images, and the multi-frame path that reads them, on real scans, the evaluation makes its own from the classic CT, MR, and PET series it downloads, in memory on the runner, through the module text_evaluation_lce, and measures them again as a stratum of their own (idc-measure --converted, through text_evaluation_converted). The conversion is built on pydicom and follows PS3.3’s rules for these IODs (A.70 to A.72 and C.7.6.16.2.25): attributes that every image shares and that the IOD defines at the top level stay there, as the shipped tables of PS3.3 decide; attributes of a Functional Group Macro move into it, shared where its item is the same for every frame; every other attribute, standard or private, goes into the Unassigned Shared or Per-Frame Converted Attributes Sequence; Frame Anatomy codes Body Part Examined by the code that PS3.16 Annex L gives it, generated with the other standard tables into anatomic_regions.json; and each frame’s Conversion Source names its image. It never changes a pixel: each frame holds the stored values that a run gives the text detector for its classic image, in the same layout, and an image that the IOD cannot hold unchanged, such as one in MONOCHROME1, with a Modality LUT, or with bits the IOD does not allow, is counted as skipped by a code instead. The tests convert synthetic series of each modality and check that every frame reads back identically, and dciodvfy, in the DICOM validators job, finds no error in the converted instances.

Images of phantoms are not patient data, so for them alone the module text_evaluation_phantom_report also gives each case’s full results and previews: every frame’s boxes for each setting, and PNG crops of each region away from text and of each injected text not fully covered, with an ATTRIBUTION.md that credits each collection under its licence. It takes only phantom sources, by their type, and reads only files of an allow-listed phantom collection that name that collection as their archive’s project. The allow-listed collections are CC-Radiomics-Phantom-3, RIDER PHANTOM PET-CT, and VICTRE’s in-silico breast phantoms, each a collection whose every subject is a phantom. MRI-DIR is not listed: its physical phantom is porcine, which the evaluation does not use, and its other subjects are synthetic images derived from patients, which are only counted. It refuses any frame not of the synthetic tier or the allow-listed phantoms’ tier, so that no frame of a patient is drawn, even with synthetic text burned into it.

Before any detection, the module text_evaluation_inventory counts what each approved collection’s files are, so that sampling can be planned from the counts: by SOP Class, Modality, a fixed list of manufacturers, Rows and Columns, pixel spacing, Number of Frames, Image Type values such as LOCALIZER, Burned In Annotation, Recognizable Visual Features, Photometric Interpretation, Bits Stored, and Transfer Syntax, singly and in fixed crosses, with the distinct patients, studies, and series. Each label is a defined term or standard value, a fixed bin, or one of the codes absent, malformed, and other, so the inventory, labelled pymedphys-deid-dicom-inventory/1, quotes no value, identifier, or path.

Today’s model and each further text detection model that passes vetting are measured through the same harness, each through an adapter in the module text_evaluation_models that only the evaluation can select. An adapter pins the model’s weights by URL and SHA-256 and refuses any others, records the licences of its code and its weights, each the Apache License 2.0 or one at least as permissive, and says how a rendering becomes the model’s input and what its output is. A model whose output is a map of the probability of text, as today’s is, takes the grid of post-processing settings from one pass of the network; a model that gives boxes is measured at each of its own post-processing settings, and the network runs again only for a setting that changes its input. The summary’s method names the model, its digest, its licences, and its training data as its publishers describe it. Beside today’s model, the module adapts RapidOCR’s conversions of PaddleOCR’s PP-OCRv6 medium and tiny and PP-OCRv5 server and mobile detection models, which RapidOCR runs with today’s input and output, and adapts PaddlePaddle’s own ONNX files of the same models and of PP-OCRv6 small on Hugging Face, each pinned at a commit, with the normalisation that each one’s inference.yml gives at that commit. Each of these records how its publishers run it, from that file and PaddleX’s defaults: the longer side scaled down to at most 960 pixels and the model’s own thresholds. A model so recorded is measured both at those settings (published_variant and published_point) and at today’s, rather than at one chosen beforehand. At its publishers’ settings, a rendering is sized exactly as PaddleX sizes it, each side truncated and then rounded to a multiple of 32, and resized by OpenCV’s cv2.resize, as their pipeline does, with their normalisation’s arithmetic; OpenCV is installed only for the evaluation’s own CI runs, never as a dependency. Since text strokes one to three pixels wide can cross a threshold under a sub-pixel shift, the module text_evaluation_parity measures what the resize alone changes: each frame through the same model at the same points with each resize, counting the regions that only one gives and the texts that only one covers fully. The Text Detection Model Pins workflow, started by hand, checks that a GitHub-hosted runner can download each pinned model and that each has its pinned SHA-256, printing only each pin’s URL, host, size, and hash result.

Beside the models, the module text_evaluation_rules holds a rule that needs no model, measured through the same harness at each of its own settings: it finds connected components of a glyph’s size at a frame’s least or greatest value, where devices often draw their overlays, joins glyphs that lie close together along a line into one box, and grows each box by a margin. It serves as a comparator, and, joined with a model’s boxes so that a region is boxed where either boxes it, as a candidate to combine with a model. Like the adapters, only the evaluation can select it.

Models are measured in two tiers. The adoptable tier is the adapters above, any of which could become the detector. The benchmark-only tier, in the module text_evaluation_benchmarks, measures other detectors through the same harness for comparison, such as those with runners of their own in PyTorch, OpenCV, or Tesseract: each may be under any licence that permits its use on CI, read first-hand and recorded with its evidence and its training data, and is still pinned, its runner’s packages by version and the SHA-256 of each file and its weights by URL and SHA-256. Their packages are installed on CI alone, into an environment of their own, never among PyMedPhys’s dependencies or in its lock file, and their runners run on the runner itself, never as a service, since some frames are real patients’. Their summaries, pages, and assessments are marked benchmark-only, and none can be adopted.